Gph550t5l 4p 28W UVC Ozone Free 254nm Disinfection Lamp for Air Purify to Kill Bacteria HVAC Duct System

Gph550t5l 4p 28W UVC Ozone Free 254nm Disinfection Lamp for Air Purify to Kill Bacteria HVAC Duct System

The SDE range has 8 models in the range and options to allow flexible installation, the SDE Range is ideal for under sink,whole house, borehole, swimming pool etc.

REQUIREMENT
* Maximum operating pressure: 8bar (116 psi)
* Ambient water temperature: 2 - 40 ℃ (36 - 104 ℉)
* Iron < 0.3ppm (0.3 mg / L)
* Hardness < 7gpg (120 mg / L)
* Turbidity < 1 NTU
* UV transmittance > 75%
Send Inquiry
Product Introduction

We adhere to the 20-year focus, and insist on deepening and expanding in the ultraviolet light sterilizer, Ultraviolet Water Treatment, Ultraviolet Water Sterilizer System field. The company is committed to research and development to create solutions with corporate characteristics, leading the industry to intelligentization, comprehensively improving the management level and economic benefits, and bringing more contributions to society. We are committed to excellence in all that we do, and we strive to exceed our customers' expectations every day. We have long supported each other, helped and made whole, giving full play to enthusiasm, creativity, and a high degree of execution and dedication of the workforce.


IMPROVES QUALITY OF HOME DRINKING WATER

Aquapro ultraviolet water sterilizer is a simple process. The 254nm energy coming from the UV lamp needs to reach the target microorganism in the water supply.


CHEMICAL-FREE WATER TREATMENT

Once microorganisms are exposed to sterilight ultraviolet water sterilizer they are rendered ‘inactive’ and can no longer replicate – meaning they can no longer produce colonies.


FEATURES

High quality UV ballast meets international certification such as CE,UL standard

Reliable High-performance UV lamp,rigorously tested to provide consistent output over the entire lamp life

Controller will go into alarm if the lamp fails

UV chamber with great welding process which enables to pass 1.04MPa 1 00,000 times water hammer test Perfect for a wide range of single-faucet, point-of-use or low flow point-of-entry water treatment solutions in homes, cottages, or OEM applications.


ECONOMICAL & EFFECTIVE

Whole house UV sterilizer

Safe, reliable and easy to apply

NO moving parts to wear out or break

NO disinfection by-products (DBP’s) or residuals

NO resistance as with chlorine and antibiotics

NO regrowth of viruses, bacteria and parasites

Lower capital investment when compared to chlorine or ozone systems


EASY INSTALLATION & OPERATION

Water sterilization system

Low power consumption

No hazardous chemicals to store and/or handle

Simple maintenance, only yearly lamp replacement (provided water quality parameters are met)

Immediate contact time (no need for contact or storage tanks)

No change in water chemistry

No effect on taste or odour of water


SPECIFICATION


Model

Flow rate

(GPM)

Reactor dimension

In/outlet port

Package size (cm)

Lamp power

SDE-0040.3195 X 50.8mm1/4"female47 X 39 X 51 /15sets4w
SDE-0060.5255 X 50.8mm1/4"female47 X 39 X 51 /15sets6w
SDE-0121310 X 50.8mm1/4"female52.5 X 39 X 52 /15sets12w
SDE-0162370 X 63.5mm1/2"male57 X 40 X 52 /15sets16w

SDE-025

6

590 X 63.5mm

1/2”male

79.5 X 28 X 41.5 /8sets

25w

SDE-030

8

910 X 63.5mm

3/4"male

119 X 28 X 41.5 /8sets

30w

SDE-035

9

950 X 63.5mm

3/4"male

119 X 28 X 41.5 /8sets

35w

SDE-04010885 X 63.5mm3/4"male112.5 X 28 X 41.5 /8sets40w
SDE-05512950 X 63.5mm3/4"male112.5 X 28 X 41.5 /8sets55w


WORKING PRINCIPLE


4


TYPICAL INSTALLATION RECOMMEND


5


PRODUCT APPLICATION

6789
Tap water

Sanitary water disinfection

Coffee machine

Drinking water machine


FAQ


Q1: Principle of Operation

UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.


Q2:Limitation of Use

The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.


Q3:Water Quality (In)

Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels


With our leading technology at the same time as our spirit of innovation, mutual cooperation, benefits and advancement, we will build a prosperous future with each other with your esteemed firm for Gph550t5l 4p 28W UVC Ozone Free 254nm Disinfection Lamp for Air Purify to Kill Bacteria HVAC Duct System. Our company will always adhere to the enterprise spirit of 'science, rigor, innovation, and dedication', and stick to the business philosophy of 'science first, quality first, service first'. Through the combination of traditional channels and Internet channels, we have formed a complete marketing context, which makes the way of trade more abundant.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry