Water Filter Spare Parts RO UV Ultra Violet Lamp Sterilizer
REQUIREMENT
* Maximum operating pressure: 8bar (116 psi)
* Ambient water temperature: 2 - 40 ℃ (36 - 104 ℉)
* Iron < 0.3ppm (0.3 mg / L)
* Hardness < 7gpg (120 mg / L)
* Turbidity < 1 NTU
* UV transmittance > 75%
Our company's UV systems for water treatment, UV light water purifier, best UV water purifier for home have been continuously improved in variety, output and quality, and are well received by domestic and foreign users. We give each customer a dedicated operator to regularly feed back cargo information to facilitate timely and effective communication. We walk with excellence and welcome all units to choose the series of products produced by our company. We are willing to cooperate with you loyally and develop together. Our logistics team ensures that all orders are delivered on time and in good condition, no matter where in the world they are going.
IMPROVES QUALITY OF HOME DRINKING WATER
Aquapro ultraviolet water sterilizer is a simple process. The 254nm energy coming from the UV lamp needs to reach the target microorganism in the water supply.
CHEMICAL-FREE WATER TREATMENT
Once microorganisms are exposed to sterilight ultraviolet water sterilizer they are rendered ‘inactive’ and can no longer replicate – meaning they can no longer produce colonies.
FEATURES
High quality UV ballast meets international certification such as CE,UL standard
Reliable High-performance UV lamp,rigorously tested to provide consistent output over the entire lamp life
Controller will go into alarm if the lamp fails
UV chamber with great welding process which enables to pass 1.04MPa 1 00,000 times water hammer test Perfect for a wide range of single-faucet, point-of-use or low flow point-of-entry water treatment solutions in homes, cottages, or OEM applications.
ECONOMICAL & EFFECTIVE
Whole house UV sterilizer
Safe, reliable and easy to apply
NO moving parts to wear out or break
NO disinfection by-products (DBP’s) or residuals
NO resistance as with chlorine and antibiotics
NO regrowth of viruses, bacteria and parasites
Lower capital investment when compared to chlorine or ozone systems
EASY INSTALLATION & OPERATION
Water sterilization system
Low power consumption
No hazardous chemicals to store and/or handle
Simple maintenance, only yearly lamp replacement (provided water quality parameters are met)
Immediate contact time (no need for contact or storage tanks)
No change in water chemistry
No effect on taste or odour of water
![]() | ![]() | ![]() |
SPECIFICATION
Model | Flow rate (GPM) | Reactor dimension | In/outlet port | Package size (cm) | Lamp power |
| SDE-004 | 0.3 | 195 X 50.8mm | 1/4"female | 47 X 39 X 51 /15sets | 4w |
| SDE-006 | 0.5 | 255 X 50.8mm | 1/4"female | 47 X 39 X 51 /15sets | 6w |
| SDE-012 | 1 | 310 X 50.8mm | 1/4"female | 52.5 X 39 X 52 /15sets | 12w |
| SDE-016 | 2 | 370 X 63.5mm | 1/2"male | 57 X 40 X 52 /15sets | 16w |
SDE-025 | 6 | 590 X 63.5mm | 1/2”male | 79.5 X 28 X 41.5 /8sets | 25w |
SDE-030 | 8 | 910 X 63.5mm | 3/4"male | 119 X 28 X 41.5 /8sets | 30w |
SDE-035 | 9 | 950 X 63.5mm | 3/4"male | 119 X 28 X 41.5 /8sets | 35w |
| SDE-040 | 10 | 885 X 63.5mm | 3/4"male | 112.5 X 28 X 41.5 /8sets | 40w |
| SDE-055 | 12 | 950 X 63.5mm | 3/4"male | 112.5 X 28 X 41.5 /8sets | 55w |
WORKING PRINCIPLE

TYPICAL INSTALLATION RECOMMEND

PRODUCT APPLICATION
![]() | ![]() | ![]() | ![]() |
| Tap water | Sanitary water disinfection | Coffee machine | Drinking water machine |
FAQ
Q1: Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.
Q2:Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Q3:Water Quality (In)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
In the face of fierce market competition and customer demand for continuous product innovation, we will continue to innovate as always, develop in the direction of high quality and high efficiency, and repay customers with better Water Filter Spare Parts RO UV Ultra Violet Lamp Sterilizer. We adhere to the people-oriented business philosophy and take the cultivation of first-class talents as a basic principle of the enterprise. Our aim is to do things with a sense of responsibility and be a person with a grateful heart. Your satisfaction is our pursuit.