UV-C LED News: Ams Osram Charts UV-C Performance, Crystal IS And Nichia (UPDATED)

A partnership between ams Osram and the University of Padua has revealed germicidal ultraviolet (GUV) research that charts the dose of UV-C radiation relative to exposure time to deactivate pathogens such as the coronavirus — an exercise that may prove especially valuable for applications such as upper-air disinfection systems. Crystal IS, meanwhile, has a new UV-C emitter called the Klaran LA that it says can deliver 100 mW with what the company calls (but doesn’t define) extended lifetimes. Nichia has also added a UV-C component in the NC4U334BR product that integrates multiple emitters for water disinfection systems.

UV-C research

We’ve covered research on UV-C technology repeatedly relative to deactivation of pathogens including the SARS-CoV-2 coronavirus. Early on in the COVID-19 pandemic, for instance, we covered Boston University work with Signify lamps that said UV-C radiation could approach 100% elimination of SARS-CoV-2. We later covered the germicidal performance of LEDs including Nichia components studied by Nagasaki University. But much of that work has shared a common trend in that the research sought to prove that a given dosage of UV-C energy could immediately deactivate pathogens such as SARS-CoV-2.

Editor's note: With regard to GUV usage, "dose" typically refers to the output power of the UV-C light engine or source. "Dosage" is the dose (output power, typically in milliwatts) combined with time (typically a metric of mJ/cm2).

The ams Osram and University of Padua work we will cover here is a bit different. The research team recognized that disinfection systems, especially some that can best leverage LEDs, might not operate instantaneously. For example, an upper-air disinfection system might realistically require multiple passes of air through the system to deactivate the virus. So the team established the dosage levels for immediate deactivation but also tested a broad range of lower radiation levels relative to the time to deactivation.

The team designed a custom system and mixing chamber, with reflective UV-C surfaces, that is based on low- and high-power Osram UV-C LEDs. The two different power classes within the Oslon UV 3636 portfolio radiated at 4 and 42 mW, respectively. All of the LEDs radiated at 275 mW and the system was located 300 mm from the pathogens.

Radiation at a dosage of 3.6 mJ/cm2 was shown to deactivate 99.99% of the pathogens instantaneously, or what is referred to as a log4 reduction. At the lower radiation dosage of 2.7 mJ/cm2 the system achieved a log3 or 99.9% reduction in pathogens. But what about much lower dosage levels?

As stated before, the test system could cover a broad output power or dosage range. So the researchers tested the system at power levels of 1100 W/m2, 0.085 W/m2, and 0.008 W/m2. The dosage would be determined by exposure time, and the team sought to create scenarios that delivered equivalent dosage. The highest-power setting was used for 13 sec to deliver a dosage of 1.43 mJ/cm2, the middle-power level required 180 sec to deliver a dosage of 1.52 mJ/cm2, and the lower-power level needed 1800 sec to yield dosage of 1.46 mJ/cm2. The three tests delivered -1.46log, -1.17log, and -1.61log reductions in pathogens respectively. Product developers will be able to learn from this methodology to apply the results in developing systems that generally aren’t intended to deactivate pathogens immediately but that operate continuously over time.