Feb 17, 2022 Leave a message

Reflective Technology Provides Advancement in UV Technology

UV technologies


The term pressure used to describe the UV systems below refers to the style of mercury lamp used in the UV system and the pressure of the gas inside the lamp, not the pressure of the water being treated. Medium-pressure lamps have a continuous output spectrum ranging from 200 to 400 nm, with the spectrum being unique to each manufacturer. Low-pressure lamps produce two narrow UV output lines, one at 185nm and one at 254 nm. The 185 nm line produces ozone in air and is filtered out for many applications by selecting the proper quartz used to make the lamp.

Medium pressure. Medium-pressure systems have been used primarily for water disinfection for many years. These systems typically have a stainless steel chamber that fits in-line with the plumbing and has the lamp located perpendicular to the flow. This makes for a compact system which can be retrofitted to existing plumbing. The controls and ballast are typically housed in a cabinet nearby. The technology does, however, have some drawbacks when compared with low-pressure units. Medium-pressure systems use more energy, have a shorter lamp life and operate at a much higher lamp surface temperature (up to 1,600°C/2,912°F ) than a comparable low-pressure system.


Low pressure – conventional. The most recognizable UV systems in use today are systems that utilize low-pressure mercury lamps. These units are typically constructed in a stainless steel pressure vessel with the lamps installed parallel to the water flow. Chamber diameter, the number of lamps and the lamp length determine the capacity of the equipment. With minor improvements, this design has been in place for over 50 years. A major drawback to this design (as well as the medium pressure systems discussed above) is the fact that stainless steel absorbs about 80 percent of the UV light that impinges on its surface. This greatly increases the number of lamps and energy consumption required to achieve the desired level of UV treatment, which has added to the market perception that UV treatment carries a high operating cost.


Earlier attempts to reduce operating costs. There have been a number of attempts to improve the performance of UV systems by replacing the stainless steel-walled chambers with designs that overcome the inherent lossy (dissipation of electrical energy) nature of conventional chambers. A number of designs use an external reflector made of aluminum. Aluminum has a much higher level of reflectivity of UV (generally 80 to 90 percent or more) than stainless steel. In one such design, the flow tube is in the center, with lamps and parabolic reflectors surrounding the flow. This design provides an improved reflection of the UV, however, most of the UV is outside the flow of water, limiting the overall efficiency. Another drawback is that the systems can get quite large for higher flows.

Other systems use the property that light incident on a surface at a very shallow angle is almost completely reflected. These systems have the lamps at one or both ends of a long flow tube, so that most of the UV light that does reach the flow tube surface is reflected back into the water. Introducing the light efficiently into the long flow tube from its end is one of the challenges limiting the efficiency of this chamber design .


Send Inquiry

whatsapp

Phone

E-mail

Inquiry