Aug 05, 2022 Leave a message

UV Radiation Dose

Ultraviolet radiation intensity: The radiation power per unit area irradiated vertically by ultraviolet rays, expressed in mw/cm2, the greater the ultraviolet power, the closer the irradiation distance, the greater the ultraviolet intensity.


Sterilization rate: (the number of bacteria in the spiked raw water - the number of bacteria after sterilization by the sterilizer) / the number of bacteria in the spiked raw water x 100%.


Ultraviolet radiation dose:the product of radiation intensity and irradiation time,expressed in mJ/cm2,which is an important parameter of the sterilization power of ultraviolet sterilizers.The irradiation dose is proportional to the sterilization rate.The greater the irradiation dose,the higher the sterilization rate.Similarly,the irradiation dose is proportional to the irradiation time.The longer the irradiation time,the higher the sterilization rate.The ultraviolet sterilizers produced by Agua Topone. have an irradiation dose of ≥30mJ/cm2.


Depending on the type of microorganism,the time and dosage of UV sterilization are also different.Different bacterial species have different absorption peaks for UV light.For example,the maximum absorption wavelengths of DNA and E.coli are both 265 nm,while the maximum absorption wavelengths of Cryptosporidium and bacteriophage are 261 nm and 271 nm,respectively.Therefore,the required sterilization time should also vary.When the ultraviolet radiation intensity is 3×104 μW/cm2,the time required to kill viruses and bacteria, mold spores,and algae bacteria is 0.1-1.0s,1.0-8.0s,and 5.0-40.0s,respectively.According to the research team of Dong Xiaoping, an expert from the Institute for Viral Disease Prevention and Control of the Chinese Center for Disease Control and Prevention,UVC irradiation with an intensity greater than 90 μW/cm can kill the SARS virus in 30 minutes.

BacteriaThe UV dose required for killing (mJ/c㎡)
Proteusvulgaris 3.6
Streptococcus hemolytica7.5
Shigella4.3
Staphylococcus albus9.1
Parashigella4.3
Staphylococcus aureus9.3
Eberzei typhi4.5
Hemolytic Streptococcus10.6
E. coli5.4
Streptococcus faecalis11.9
Vibrio cholerae6.5
Mycobacterium tuberculosis10.0
Pseudomonas aeruginosa10.5
Bacillus subtilis21.6
Salmonella15.2
Bacillus subtilis (spore)33.3
Baker's yeast8.8
Aspergillus flavus120.0
Wine yeast13.2
Aspergillus niger264.0
Brewer's yeast18.9
Rhizopus niger222.0
Saccharomyces cerevisiae19.6
Poliovirus6.0
Baguette-binding yeast21.1
Bacteriophage (E. coli)6.6
Wilhelmin37.3
Influenza virus6.6
Pichia38.4
Infectious Cold Virus8.0
Chlorella vulgaris (algae)22.0
Tobacco mosaic virus440.0
Nematode eggs92.0
Paramecia200.0

Under the condition of sufficient UV dose,the inactivated virus and bacteria will not be revived,but when the dose is insufficient,many virus and bacteria inactivated by UV radiation can repair their damaged structures through the assistance of light.When the ultraviolet dose is the same,high-intensity,short-time or low-intensity,long-time irradiation can be used to achieve the purpose of sterilization.


In addition,UV sterilization systems not only treat water but also syrups,juices and similar solutions.In the selection of UV dose, in addition to referring to the definitions of relevant standards,it should also consider whether there are some special organisms in the water body,such as some molds,which require higher doses to kill.


The above is the introduction of ultraviolet radiation dose and sterilization dose for different bacteria.In fact,the ultraviolet radiation dose is only one of the many indicators for choosing a UV sterilizer.To choose a UV sterilizer that suits your needs,you also need to To master more knowledge,you are welcome to subscribe to Diamond UV,we will continue to update more UV sterilizers for you,and take you to a new height of UV!


Send Inquiry

whatsapp

Phone

E-mail

Inquiry